  Datasheet File OCR Text:
 Slim Connector-Terminal Block Conversion Units
XW2D
CSM_XW2D_DS_E_1_2
New Slim Connector-Terminal Block Conversion Units.
* Mounting area reduced by 35% (in comparison with 40-pole XW2B Units) to contribute to downsizing control panels and automatic equipment. * Fallout prevention for terminal screws. * Round or forked crimp terminals can be used. * Mount to DIN Track or via screws. Unique DIN Track lock can maintain open status during DIN Track attachment and removal. * Terminal cover can be locked open. * Screw terminals are arranged by color in groups of five to simplify counting terminal numbers.
Ordering Information
Connectors
Mounted Connector No. of poles 20 34 XG4A MIL Connectors Model XW2D-20G6 XW2D-34G6 XW2D-40G6 40 XW2D-40G6-RF *1 XW2D-40G6-RM *2 50 20 XG4C MIL Connectors 34 40 50 20 MR Sockets 34 50 20 MR Plugs 34 50 XW2D-50G6 XW2D-20C6 XW2D-34C6 XW2D-40C6 XW2D-50C6 XW2D-20X6 XW2D-34X6 XW2D-50X6 XW2D-20Y6 XW2D-34Y6 XW2D-50Y6 Dimension A 79 128 149 149 149 184 79 128 149 184 79 128 184 79 128 184 Dimension B 57 100 110 110 110 144 57 100 110 144 57 100 144 57 100 144 Mounted Connector model XG4A-2031 XG4A-3431 XG4A-4031 XG4A-4031 XG4A-4031 XG4A-5031 XG4C-2031 XG4C-3431 XG4C-4031 XG4C-5031 MR-20RFD2 *3 MR-34RFD2 *3 MR-50RFD2 *3 MR-20RMD2 *3 MR-34RMD2 *3 MR-50RMD2 *3 Cable Connector model XG4M-2030-T XG4M-3430-T XG4M-4030-T XG4M-4030-T XG4M-4030-T XG4M-5030-T XG4M-2030-U XG4M-3430-U XG4M-4030-U XG4M-5030-U MR-20M *3 MR-34M *3 MR-50M *3 MR-20F*3 MR-34F *3 MR-50F *3
*1. This model has built-in bleeder resistance and is used for inputs to Units with Fujitsu connectors, i.e., the CJ1W-ID231/-ID261/-MD261. *2. This model has built-in bleeder resistance and is used for inputs on Units with MIL connectors, i.e., the CJ1W-ID232/-ID262/-MD263/-MD563. *3. The MR Connector is made by Honda Tsushin Kogyo.
Accessories (Order Separately)
Connecting Cables for Connector-Terminal Block Conversion Units Refer to the XW2Z Datasheet.
Ratings and Specifications
Rated current Rated voltage Insulation resistance Dielectric strength 1A 125 VAC, 24 VDC 100 M min. (at 500 VDC) 500 VAC for 1 min (leakage current: 1 mA max.)
Ambient operating tem0 to 55C perature
1
XW2D
Dimensions
XW2D-@@G6 Mounted Connector: XG4A MIL Connector
XG4A MIL Connector A B Two, 4.5 dia. (39.1) 17.6
(Unit: mm)
Wiring Diagram (Example for Terminal Block with 50 Poles)
Mounted Connector
2 1
4 3
6 5
46 48 50 45 47 49
6 40
Triangular mark
7 DIN Track lock
(4.5) 1.2
7 5.8 M3
39
A1 A2 A3 B1 B2 B3
Terminal Block
A23
A24
A25
B23
B24
B25
7
Note: There is only one DIN Track lock located in the center of the terminal block for a 20-pole Unit.
Note: For all models, the odd-numbered pins on the Connector correspond to row A on the terminal block and the even-numbered pins on the Connector correspond to row B on the terminal block.
XW2D-40G6-RF
Connector (XG4A-4031)
Connector pin No.
2 1 4 3 6 5 8 10 12 7 9 14 16 18 20 22 24 26 28 30 32 34 36 38 40 21 23 25 27 29 31 33 35 37 39
XW2D-40G6-RM
Connector (XG4A-4031)
Connector pin No.
2 1 4 3 6 5 8 7 10 12 9 14 16 18 20 22 24 17 19 21 23 26 28 30 32 34 36 38 40 25 27 29 31 33 35 37 39 11 13 15
11 13 15 17 19
Triangular mark
Triangular mark
Terminal No.
A1 A2 B1 B2
A3 B3
A4 B4
A5 A6 B5 B6
A7 B7
A8 A9 A10 B8 B9
B10
A11 B11
A12 B12
A13 B13
A14 B14
A15 B15
A16 B16
A17 B17
A18 B18
A19 B19
A20 B20
Terminal No.
A1 A2 B1 B2
A3 B3
A4 B4
A5 A6 B5 B6
A7 B7
A8 A9 B8 B9
A10 B10
A11 B11
A12 B12
A13 B13
A14 B14
A15 B15
A16 B16
A17 B17
A18 B18
A19 B19
A20 B20
Terminal Block
Note: The dimensions shown here are the same as the XW2D-40G6.
Terminal Block
Note: The dimensions shown here are the same as the XW2D-40G6.
XW2D-@@C6 Mounted Connector: XG4C MIL Connector
A B XG4C MIL Connector Two,4.5 dia. (21.1) 17.6
Wiring Diagram (Example for Terminal Block with 50 Poles)
Mounted Connector
2 1
4 3
6 5
46 48 50 45 47 49
6 40
Triangular mark
7 DIN Track lock
(4.5) 1.2
7 5.8 M3
39
A1 A2 A3 B1 B2 B3
Terminal Block
A23 A24 A25 B23 B24 B25
7
Note: There is only one DIN Track lock located in the center of the terminal block for a 20-pole Unit.
Note: For all models, the odd-numbered pins on the Connector correspond to row A on the terminal block and the even-numbered pins on the Connector correspond to row B on the terminal block.
2
XW2D
XW2D-@@X6 Mounted Connector: MR Socket
A B Two, 4.5 dia. (28.2) 17.6
Wiring Diagram (Example for Terminal Block with 50 Poles)
Mounted Connector
33 34 35
6 40
48 49 50 32 16 17 18
19 20 1 2 3
7 DIN track lock
(4.5) 1.2
39 7 5.8 M3
1 2
7
3 4
5 6
17 19 16 18 20
45 47 49 46 48 50
Terminal Block
Note: Connector pin numbers correspond 1-to-1 to terminal block numbers on all models.
Note: There is only one DIN Track lock located in the center of the Connector for a 20-pole Unit.
XW2D-@@Y6 Mounted Connector: MR Plug
A B Two, 4.5 dia. (25.9) 17.6
Wiring Diagram (Example for Terminal Block with 50 Poles)
Mounted Connector
1
6 40
2
3 19 20
16 17 18 32 48 49 50
33 34 35
7 DIN Track lock (4.5) 7 1.2 5.8 M3 39
1 2
7
3 4
5 6
17 19 16 18 20
45 47 49 46 48 50
Note: There is only one DIN Track lock located in the center of the terminal block for a 20-pole Unit.
Terminal Block Note: Connector pin numbers correspond 1-to-1 to terminal block numbers on all models.
3
XW2D
Safety Precautions
Precautions for Correct Use
Wiring
* Always turn OFF the power supply before wiring. Otherwise, cables or other conductors can short the terminals and cause the Unit to fail. * Do not connect or disconnect Connectors with the power turned ON. Otherwise, it may cause malfunctions.
Mounting Units to and Removing Units from DIN Track
* XW2D Connector-Terminal Block Conversion Units can be mounted side-to-side on DIN Track. * Secure both ends of the XW2D with End Plates. * When removing the Unit from a DIN Track, insert a flat-head screwdriver into the slider and pull the lock out.
Wiring Terminal Blocks
Using Crimp Terminals (With a Terminal Block with M3 Screws)
Round crimp terminals
3.2 mm dia.
5.8 mm max. 3.2 mm 5.8 mm max.
Forked crimp terminals
Applicable crimp terminals Round crimp terminals Forked crimp terminals 1.25-3 1.25Y-3
Applicable wires AWG 22 to 16 (0.30 to 1.25 mm2) AWG 22 to 16 (0.30 to 1.25 mm2)
Handling M3 Screw and Round Terminals
Raise the M3 screw with a Phillips screwdriver as shown in diagram (1) and slide the screw toward you to keep the space open. Follow the steps in diagrams (1) and (2) below when using round crimp terminals.
Terminal Screw Tightening Torque
Use a tightening torque of 0.7 N*m when connecting wires or crimp terminals to the terminal block.
A
B
4
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
2008.11 In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
http://www.ia.omron.com/
OMRON Corporation
(c)Copyright OMRON Corporation 2008 All Right Reserved.


▲Up To Search▲   

 
Price & Availability of XW2D-40C6

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X